0086-550-7096433
    Disclaimer|Sitemap| Contact
1.jpg
  • 1.jpg

YFFB flat cable

The product has cold resistance, soft, wear resistance, oil resistance and other characteristics, su…
Description

The product has cold resistance, soft, wear resistance, oil resistance and other characteristics, suitable for the rated AC voltage up to and including 0.6/1kV cold resistance, oil resistance and other special requirements of mobile electrical connection cable, the product has been widely used in metallurgy, electric power, ships, automobile manufacturing and other industries.


Ii. Product standard Q/HL009-2004. Flame retardant performance test in accordance with GB12666-90


Three: use characteristics


1. Ac rated voltage: U0/U 0.6/1kV Z.UI High operating temperature: 105℃ Z.ui Low ambient temperature: -40℃ for fixed installation


2. The temperature of cable installation and laying should not be lower than -25℃.


3. The allowable bending radius of the cable is 12 times of the cable diameter


Four: Basic model and name


Table 1 Model name


YVFR Nitrile insulated and jacketed power flexible cable


YVFRP nitrile insulated and jacketed copper braided shielded power cable


Zr-yvfr flame retardant nitrile insulated and sheathed power flexible cable


Zr-yvfrp flame retardant nitrile insulation and sheath copper braided shield flexible power cable


YVFPR nitrile insulated and sheathed flexible cable


YVFRP2 Nitrile insulated and sheathed copper foil shielded power flexible cable


YVFRB power soft flat cable with nitrile insulation and sheath


YVFRPB nitrile insulated and jacketed copper braided shield soft flat power cable


YVFB nitrile insulated and jacketed mobile flat cable


YVFPB nitrile insulated and jacketed copper braided shield mobile flat cable


YVFP2B Nitrile insulated and sheathed copper foil shielded mobile flat cable


Zr-yvfrpb flame retardant nitrile insulated and jacketed copper braided shield mobile flat cable cable


Nh-yvfr Refractory nitrile insulated and sheathed power flexible cable


Nh-yvfrp refractory nitrile insulation and sheath copper braided shield power cable


KYVFR Nitrile insulated and jacketed control flexible cable


KYVFRP nitrile insulated and sheathed copper braided shield control flexible cable


Zr-kyvfr flame retardant nitrile insulated and jacketed control flexible cable


Zr-kyvfrp flame retardant nitrile insulated and sheathed copper braided shield control flexible cable


KYVFPR nitrile insulated and jacketed control flexible cable


KYVFRP2 Nitrile insulated and sheathed copper foil shielding control flexible cable


YVFP nitrile insulated and jacketed shielded power cable


KYVFP nitrile insulated and jacketed copper braided shield control cable


Zr-kyvfp flame retardant nitrile insulated and sheathed control cable


Zr-kvfp2 flame retardant nitrile insulated and sheathed copper foil shielding control cable


YVFP2 Nitrile insulated and sheathed copper foil shielded power cable


KYVFB nitrile insulated and jacketed control flat cable


Zr-yffb flame retardant nitrile composite insulation and sheath mobile flat flexible cable


Zr-yffpb flame retardant nitrile composite insulation and sheathed copper wire shielding mobile flat flexible cable


YFFB nitrile composite insulated and jacketed mobile flat flexible cable


YFFBP nitrile composite insulated and jacketed copper wire shielding mobile flat flexible cable


YFFRB nitrile composite insulation and sheath mobile flat flexible cable


YFFRBP nitrile composite insulated and jacketed copper wire shielding mobile flat flexible cable


YFF nitrile compound insulated and sheathed cable


YFFP nitrile compound insulated and sheathed copper wire shielded cable


Table 2 Code Name Meaning YVF Nitrile cable series P copper braided shield R Multi-stranded conductor B flat cable


Six: main technical indicators


1. Dc resistance of finished cable conductor (Class R) (in accordance with GB3956) refer to Table 2 in Appendix A.


The insulation resistance is not less than 50M ω /KM at 2.20 ° C.


3. Finished cable withstands ac 50HZ3.5 kV /5min voltage test without breakdown.


Browse:
Return To The Top