0086-550-7096433
    Disclaimer|Sitemap| Contact
1.jpg
  • 1.jpg

Fluoroplastic high temperature resistant power cable

This product is fit for ac rated voltage up to and including 0.6/1 kv for fixed installation, power …
Description

A: product characteristics and use

This product is fit for ac rated voltage up to and including 0.6/1 kv for fixed installation, power transmission and distribution line motor lead wire, high temperature resistance, corrosion resistance, and corrosive gas, waterproof properties, such as high temperature environment stable electrical performance, large carrying capacity, long service life, widely used in metallurgy, electric power, petrochemical, large construction, automotive and other industries.

Two: product implementation standards

Q/HHTZH001.2

Flame retardant fire resistance test to comply with gb12666-90 standard

Three: use characteristics

1. Ac rated voltage: U0/U 0.6/1kV

2. High working temperature: polyperfluoroethylene propylene (F46) J edge does not exceed 200℃

J margin of soluble polytetrafluoroethylene (PFA) does not exceed 260℃

3. Low ambient temperature: fluorine plastic J-edge and sheath

-40℃ for fixed laying, -15℃ for non-fixed laying

4. The cable installation and laying temperature should not be lower than 0℃ (fluorine plastic, silicone rubber and nitrile sheath cable should not be lower than -25℃).

5. The allowable bending radius of the single-core cable is 15 times of the cable diameter

The multi-core cable is 10 times smaller than the cable diameter

Four: basic model and M scale (including other models of high temperature resistant cables)

model

The product name

Normal operating temperature ℃

FF46

Fluoroplastic j-edge and sheath power cable

- 60-200

FF46-22

Fluorine plastic j-edge and sheathed steel tape armored power cable

- 60-200

FF46P

Fluoroplastic J-edge and sheath copper braided shielded power cable

- 60-200

ZR-F46(FV)

Fluorine plastic j-edge flame retardant PVC sheathed power cable

- 40-105

ZR-F46-22(FV22)

Fluorine plastic j-edge steel tape armored flame retardant PVC sheathed power cable

- 40-105

ZR192-FF46

PFAJ power cable with edge and sheath (raw material)

- 60-260

ZR192-FF46P

Braided shielded power cable with PFAJ edge and sheath (raw material)

- 60-260

ZR192-FF46-22

PFAJ edge and sheath steel tape armored power cable (raw material)

- 60-260

YGC-F46(FG)

Fluoroplastic j-edge silicone rubber sheathed power cable

- 60-180

YGC-F46-22(FG22)

Fluorine plastic j-edge steel tape armored silicone rubber sheathed power cable

- 60-180

YVF-F46

Fluoroplastic J-edge flame retardant nitrile polyvinyl chloride sheathed power cable

- 60-105

YVF-F46-22

Fluorine plastic J-edge steel tape armored flame retardant nitrile PVC sheathed power cable

- 60-105

Note: Add R to the original model of soft structure cable, copper wire in conductor core can be tinned.

Five: Code M name and meaning table 2

Code name

Symbol meaning

A series of codes

slightly

F(F46)

Polyperfluoroethylene propylene (F46)

YVF

Nitrile rubber

G

Silicone rubber

192

PFAJ edge and sheath

ZR(V)

Flame retardant polyvinyl chloride (flame retardant 70℃, 90℃, 105℃ three)

22

Steel tape armoured

32

Fine wire armour

P

Braided copper shield

R

Stranded conductor

Six: main technical indicators

1. Refer to Table 1 of Appendix A for dc resistance of finished cable conductor (in accordance with GB3956).

At 2.20 ℃, the j-edge resistance shall be no less than 500M ω /KM, and at 180℃, the J-edge resistance shall be no less than 10M ω /KM

3. Finished cable withstands ac 50HZ3.5 kV /5min voltage test without breakdown.


Browse:
Return To The Top