High temperature and oil resistant special cable
Description
I. Overview:
Resistance to high temperature oil special cable applies to the metallurgical, petroleum, chemical industry and power plants and other industrial and mining enterprises, under the condition of high temperature and harsh environment, such as acid, alkali, oil and water temperature conditions) for all kinds of electrical, instrumentation and automation of cable, for ac rated voltage up to and including 450/750 v control, circuit monitor and protection and situations. Ii. Model and Name:
The serial number | model | The name of the |
1 | KFF | Fluoroplastic insulated and sheathed control cable |
2 | KFFP | Fluoroplastic insulated and sheathed control cable |
3 | KFFR | Fluoroplastic insulated and jacketed control flexible cable |
4 | KFFRP | Fluoroplastic insulated and sheathed control flexible cable |
5 | KFV | Fluoroplastic insulated PVC sheathed control cable |
6 | KFVP | Fluoroplastic insulated PVC sheathed control cable |
7 | KFVR | Fluoroplastic insulated PVC sheathed control flexible cable |
8 | KFVRP | Fluoroplastic insulated PVC sheathed control flexible cable |
9 | KFV22 | Fluoroplastic insulated PVC sheathed steel tape armored control cable |
10 | KFVP22 | Fluoroplastic insulated PVC sheathed steel tape armored shielded control cable |
11 | KFVR22 | Fluoroplastic insulated PVC sheathed steel tape armored control flexible cable |
12 | KFVRP22 | Fluoroplastic insulated PVC sheathed steel tape armored control flexible cable |
13 | KFFV22 | Fluoroplastic insulated and inner sheathed PVC outer sheathed steel tape armored control cable |
14 | KFFRV22 | Fluoroplastic insulated and inner sheathed PVC outer sheathed steel tape armored control flexible cable |
Rated voltage: AC Uo/U; 2. Operating temperature: No. 1 ~ 4-60 ~ +200℃ No. 5 ~ 14-15 ~ +105℃ 3, insulation resistance (20℃) not less than 50M ω ·km 4, conductor core DC resistance (20℃) in accordance with GB3956-97 5, unarmored cable bending radius not less than 6 times of cable diameter, The bending radius of armored cable is not less than 12 times of cable diameter. 6, low installation and laying temperature: No. 1 ~ 4-45 ℃ No. 5 ~ 140 ℃
The serial number | Nominal cross section | Conductor core specification | Conductor core specification | Some cable | ||
The serial number One, two, five, six, nine, ten, thirteen | The serial number 3,4,7,8,11,12,14 | The serial number 1 ~ 4 | The serial number Five to eight | The serial number 9 ~ 14 | ||
1 2 3 4 5 | 0.2 0.5 0.75 1.0 1.5 2.5 | 1/0.52 1/0.80 1/1.0 1/1.13 1/1.38 1/1.76 | 7/0.20 16/0.20 19/0.23 24/0.20 19/0.26 32/0.20 19/0.32 30/0.25 49/0.26 | 2 ~ 44 2 ~ 30 2 ~ 19 2 to 16 2 ~ 14 2 ~ 8 | 2 ~ 61 | 7 ~ 37 7 ~ 37 7 ~ 37 4 ~ 37 |