Pressure spring thermocouple
Description
Pressure spring thermocouple through the pressure spring thermocouple ends and the surface of the measured object close to improve the reliability and accuracy of measurement. Pressure spring thermocouple and display instrument supporting use, can directly measure the temperature within the range of 0~400℃. Compression spring type thermocouple with soft extension wire, can be bent freely, has the characteristics of low thermal response time, easy to use, suitable for plastic extruder, textile, food and other industries.
Structure principle
The wreT-01 compression spring thermocouple has the same operating principle, indexing characteristics and allowable deviation, reference end (cold contact) temperature compensation, and connection to a display measuring instrument.
The wreT-01 spring type thermocouple is shown as shown, with protection tube and mounting bolt. Locking clamp, spring and thermocouple wire, etc.
Installation method
Wret-01 Compression spring thermocouple installation procedure WreT-01 compression spring thermocouple installation procedure WRET-01 Compression spring thermocouple installation procedure WRET-01 Compression spring thermocouple installation procedure WRET-01 Compression spring thermocouple installation procedure WRET-01 Compression spring thermocouple installation procedure WRET-01 Compression spring thermocouple installation procedure WRET-01 Compression spring thermocouple installation procedure WRET-01 Compression spring thermocouple installation procedure WRET-01 Compression spring thermocouple installation procedure WRET-01 Compression spring thermocouple installation procedure WRET-01 Compression spring thermocouple installation procedure
specifications
model | Degree, | Temperature range: ℃ | The thermal response time is T0.5s | Protective tube material | |
WRET-01 | E ( EA-2 ) * | 0-400. | < 5 | 1 cr18ni9ti stainless steel | |
WRNT - 01 | K of EU minus 2 times | 0-400. | < 5 | 1 cr18ni9ti stainless steel | |
specifications | Connecting bolt mm | ||||
Total length of Lmm | Protection tube L mm | ||||
1000 | 30 30 30 30 30 30 | 35 or 70 | |||
1000 | 60 60 60 60 60 60 60 60 |
Note :1) product name and model