Differential pressure transmitter
Description
The 1151/3351DP differential pressure transmitter is used to measure the level, density and pressure of a liquid, gas or steam and then convert it into a 4 ~ 20mA DC signal output. Intelligent type can communicate with HART operator, through it to set, monitor or with the host into a field monitoring system. 1151/3351DP field adjustable intelligent differential pressure transmitter is a new product developed by our company according to the requirements of the field. It can be separated from the hand operator and realize the field zero adjustment, configuration and other operations through keys. 1. Performance specifications (Zero reference range, under reference conditions, silicone oil filled, 316 L stainless steel isolation diaphragm)
1.1. Reference accuracy 1.1.1. Digital and intelligent: ±0.1% calibration range 1.1.2. Analog, linear: ±0.2% check range 1.2. Stability 1.2.1. Digital, Smart: 6 months, ±0.1%URL 1.2.2. Analog, Linear: 6 months, ±0.2%URL 1.3. Influence of ambient temperature 1.3.1. Digital and intelligent zero error: ±0.2%URL/56℃ Overall error: ±(0.2%URL+0.18% check range) /56℃ 1.3.2. Analog, linear zero error: ±0.5%URL/56℃ Overall error: ±(0.5%URL+0.5% calibration range)/56℃ 1.4. Static pressure effect 1.4.1. Zero point: ±0.2%URL at 13790kPa for range 4 to 8; Other ranges are ±0.25%URL. The zero error can be corrected online by recalibrating. 1.4.2. Range: adjustable to ±0.25% output reading /6895kPa, for range 3, adjustable to ±0.5% output reading /6895kPa 1.5. Vibration influence In any axial direction, vibration influence at 200Hz is ±0.05%URL/g 1.6. Power impact is less than ±0.005% output range/volt. | 1.7. Load effect: There is no load effect unless there is a change in the supply voltage. 1.8. Electromagnetic interference/radio frequency interference (EMI/RFI influence) from 20 to 1000MHz, when the field intensity reaches 30V/M, the output drift is less than ±0.1% range. 1.9. The zero drift affected by installation position is ± 0.25kpa at most. All zero drift can be corrected; There is no impact on the range. Measuring range: differential pressure: 0-1.3 ~ 6890KPa Static pressure: 4, 10, 14MPa 2.2. Zero and range 2.2.1. Digital and intelligent: the range and zero button of the machine can be adjusted, or the HART manipulator can be used for remote adjustment. 2.2.2. Analog, linear: range and zero point are continuously adjustable. 2.3. Zero-point positive and negative migration In zero-point negative migration, the lower limit of the range must be greater than or equal to -URL; For zero-point positive migration, the upper limit of the range must be less than or equal to +URL. Check range greater than or equal to small range. 2.4 output digital, intelligent: 4 ~ 20mA DC, the user can choose linear or square root output, digital process variables superimposed on the 4 ~ 20mA DC signal, available for the upper computer using HART protocol. Analog, linear: 4 ~ 20mA DC, linear with process pressure. |
◆ Selection mode
1151/3351DP | Differential pressure transmitter | |||||||
code | Measuring range KPa | |||||||
3 | 0-1.3 ~ 7.5 | |||||||
4 | 0-6.2 ~ 37.4 | |||||||
5 | 0-31.1 ~ 186.8 | |||||||
6 | 0-117 to 690 | |||||||
7 | 0-345 to 2068 | |||||||
8 | 0-1170 to 6890 | |||||||
code | The output | |||||||
E | 4-20mA | |||||||
S | Intelligent type | |||||||
Code name | Structural materials | |||||||
Flanges and joints | Exhaust/discharge valve | Isolation diaphragm | Pump the liquid | |||||
22 | 316 stainless steel | 316 stainless steel | 316 stainless steel | Silicone oil | ||||
23 | 316 stainless steel | 316 stainless steel | Hastelloy C | |||||
24 | 316 stainless steel | 316 stainless steel | monel | |||||
25 | 316 stainless steel | 316 stainless steel | tantalum | |||||
33 | Hastelloy C | Hastelloy C | Hastelloy C | |||||
35 | Hastelloy C | Hastelloy C | tantalum | |||||
44 | monel | monel | monel | |||||
Code name | High working pressure MPa | |||||||
B- | 4 | |||||||
C- | 10 | |||||||
D- | 14 | |||||||
code | options | |||||||
M1 | 0-100% linear indicator table | |||||||
M2 | LED display table | |||||||
M3 | LCD display table | |||||||
B1 | Pipe mounting bracket | |||||||
B2 | Plate mounting bracket | |||||||
B3 | Pipe mounting bracket | |||||||
D1 | The side relief valve is above the pressure chamber | |||||||
D2 | The side relief valve is under the pressure chamber | |||||||
Don't note | Fittings for 1/2NPT taper pipe threads | |||||||
C2 | T-thread joint M20×1.5, with a ball cone joint with a ф 14 pressure guide pipe welded at the back | |||||||
d | Flameproof d Ⅱ BT4 | |||||||
i | The Ann type ia Ⅱ CT6 | |||||||
J | Flow transmitter 4-20mA square output | |||||||
s | Stainless steel triple valve set |