Intelligent quantitative controller

An overview of the Intelligent flow quantitative controller (hereinafter referred to as the controll…
Description

An overview of the


Intelligent flow quantitative controller (hereinafter referred to as the controller) main features:


Suitable for all kinds of liquid medium flow display, calculation, quantitative control function;


Input a variety of flow sensor signals (such as vortex street, turbine, electromagnetic, Roots, elliptic gear, double rotor, orifice plate, V-cone, Amoba, mass flow and other flowmeters);


Flow input channel: can receive frequency signals and a variety of analog current signals;


Temperature input channel: can receive a variety of analog current signals;


Can provide transmitter +24V DC, +12V DC power supply, with short circuit protection function, simplify the system, save investment;


Fault tolerance function: when the temperature/density compensation measurement signal is abnormal, the corresponding manual set value is used for compensation operation;


Flow retransmission function, output flow current signal, update period of 1 second, to meet the needs of automatic control;


Meter clock and timing automatic meter reading function, printing function, provide convenience for measurement management;


Rich self-test and self-diagnosis functions make the meter easier to use and maintain;


Three-level password setting can prevent unauthorized personnel from changing the set data;


There is no potentiometer, code switch and other adjustable devices inside the instrument, so as to improve the seismic resistance, stability and reliability of the instrument;


Communication function: data communication can be carried out with the upper computer through a variety of communication methods to form an energy metering network system:


RS - 485.


RS - 232.


Main technical index of instrument


The input signal


Mold fitting:

Thermocouple: standard thermocouple -- K, E, B, J, N, T, S;

Resistance: standard thermal resistance -- Pt100;

Current: 0 ~ 10mA, 4 ~ 20mA -- input impedance ≤250 ω;

Pulse impact:

Wave shape: rectangle, sine wave and triangle wave;

Amplitude: greater than 4V;

Frequency: 0 ~ 10KHz (or according to user requirements).

The output signal


Analog output:

DC 0 ~ 10mA (load resistance ≤750 ω);

DC 4 ~ 20mA (load resistance ≤500 ω);

Switching output

Relay output -- return difference, AC220V/3A; DC24V/6A (resistive load).

The communication output

Interface mode -- Standard serial communication interface: RS-232C, RS-485;

Baud rate -- 600, 1200, 2400, 480, 9600Kbps, meter internal setting.

Feed output

DC24V, load ≤100mA;

DC12V, load ≤200mA

features

Measurement accuracy: ±0.2%FS±1 word or ±0.5%FS±1 word

Frequency conversion accuracy: ±1 pulse (LMS) generally better than 0.2%

Measuring range: -999999 ~ 999999 words (instantaneous value, compensation value);

0 to 99999999.9999 words (cumulative value)

Resolution: ±1 word

Display mode

· Large backlit screen 128×64 dot matrix LCD graphic display;

· Historical cumulative flow, instantaneous flow, medium temperature, medium density, flow (differential voltage current, frequency) value, clock, alarm status;

·0 ~ 999999 instantaneous flow

·0 to 99999999.9999 Cumulative value

·-9999 ~ 9999 temperature compensation

·-99999 to 999999 Traffic (differential pressure, frequency)