0086-550-7096433
    Disclaimer|Sitemap| Contact
1.jpg
  • 1.jpg

Anticorrosive magnetic flip level meter

Anti-corrosion type level gauge is the distinctive features of liquid medium with indicator is compl…
Description

Anti-corrosion type level gauge is the distinctive features of liquid medium with indicator is completely isolated, so in any case, is very safe, reliable, durable, and various types of liquid level meter with liquid level alarm, control switches, and implementation level or the position of the upper and lower limit offside control or alarm, interlock, or dry reed - with static pressure type fluid shift delivering resistance type liquid level transmitter, The liquid level and boundary signal can be converted into 2-line 4-20MADC standard signal to realize remote indication, detection, recording and control. Suitable for liquid level measurement in corrosive medium with high working temperature, reliable structure and long service life. Hydrofluoric acid and other corrosive medium liquid level measurement choice. Customized for customers, the temperature and pressure requirements are not high can use the company's PP material level gauge.


Stainless steel lined with PTFE anti-corrosion magnetic plate level meter using stainless steel body lined with polypropylene (PP) and polytetrafluoroethylene (PTFE) process, has a high structural strength and corrosion resistance, can be used in hydrochloric acid and other acidic liquid, alkaline liquid and organic solvents. But not suitable for concentrated nitric acid, chlorine solvent, aromatic agent, aliphatic medium liquid measurement. There are two kinds of stainless steel body lining polytetrafluoroethylene (PTFE) and stainless steel lining polypropylene (PP), suitable for the measurement of corrosive media.


PTFE is suitable for liquid level measurement in corrosive medium and high working temperature. It adopts the new technology of PTFE stretching flanging lined with stainless steel, with reliable structure and long service life. Hydrofluoric acid and other corrosive medium liquid level measurement choice.

Side mounted magnetic flip level meter (PP) suitable for hydrochloric acid, dilute sulfuric acid and other inorganic corrosive liquid measurement, due to the use of imported high strength can be close to the metal, especially PPR insulation, the product is suitable for outdoor water tank level measurement, in winter will not freeze, but not as good as PTFE type temperature and pressure resistance, When the temperature and pressure are low, this product is more cost-effective. Users can be used according to the needs of engineering, with remote transmitter, can realize local digital display, as well as the output of 4~20mA standard remote electrical signal, to meet the needs of recording instruments, or industrial process control. It can also be used with magnetic control switch or proximity switch to control the liquid level monitoring alarm or the liquid inlet and outlet equipment.


Anticorrosive magnetic plate level gauge features:


1, float as the measuring element, magnetic steel drive column display, no energy.


2, equipped with upper and lower limit switch output, can achieve remote alarm, limit control.


3. Equipped with transmitter, it can realize remote indication, detection and control of liquid level.


Installation and maintenance of anti-corrosion magnetic plate level gauge


1. The liquid level meter shall be installed vertically to ensure that the floating ball assembly moves freely up and down in the main pipe.


2, the main body of the level meter is not allowed to be near the magnetic guide, otherwise it will directly affect the correct work of the level meter.


3, after the installation of the level meter, it is necessary to use magnetic steel to correct the guidance of the turning column once so that the following zero shows red, and the above zero shows white.


4. When the level meter is put into operation, the valve of the lower liquid pipe should be opened first to let the liquid medium enter the main pipe smoothly, so as to avoid the rapid rise of the liquid medium with the floating ball component, resulting in the failure of column turning and chaos. If this phenomenon occurs, magnetic steel can be used to recalibrate after the liquid level is stable.


Basic technical parameters


1, measuring range: 300 ~ 4000㎜ (more than 5000mm can be specially customized)


2, display accuracy: ±10mm;


3, working pressure: PP: atmospheric pressure


4, medium temperature: PP: -20 ~ 70℃;


5, medium density: ≥0.5g/cm3;


6, medium viscosity: ≤0.4Pa·S;


7, process connection: DN2025/50/80/150 PN1.0 (implementation of the standard HG20592-20635-97), if you need other standards can be manufactured according to customer requirements.


8, liquid material: /PP and so on


9, float material: 316L, PVC/UPVC/CPVC/PP, PTFE, titanium, etc.


Browse: